BASE LD-1800 Plug in loop detector ***Discontinued - Replaced by LMA-1800***

BASE ITEM: LD-1800
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***
BASE LD-1800 Plug in loop detector  ***Discontinued - Replaced by LMA-1800***

BASE LD-1800 Plug in loop detector ***Discontinued - Replaced by LMA-1800***

BASE ITEM: LD-1800
Regular price $99.00
/
  • Free shipping on most items over $200
  • We have 15+ years of industry experience
  • GSA, Net 30 and purchase orders available
Shipping calculated at checkout.

Description

Description

***EDI LMA-1800 will ship if ordered***

BASE LD-1800 Loop Detector - **EDI LMA-1800 is the replacement for the LD-1800**

**direct replacement for discontinued BASE LD-1500**


Single channel with dual programmable solid state outputs. Printed circuit board (pcb) mounted. The DEFLECTOMETER display helps optimize the proper sensitivity setting to detect all vehicles including motorcycles. NO MORE GUESS WORK WHEN SETTING SENSITIVITY OR FREQUENCY!

 

  • DEFLECTOMETER®: The front panel 7-segment LED DEFLECTOMETER®
    provides visual feedback and assistance for setting the correct sensitivity,
    reading the frequency of the loop, reporting Loop Faults, and indicating Delay
    & Extension Timing functions.
  • Sensitivity Meter: With a typical size vehicle over the
    roadway loop, the DEFLECTOMETER® functions as a Sensitivity Meter. The optimum
    sensitivity setting should provide a reading of “5”. You can adjust the
    DEFLECTOMETER® reading by using the front panel UP or DOWN sensitivity buttons.
    Automatic quantitative feedback of the loop system operation ensures that the
    detector is set to the most optimum sensitivity level to detect ALL vehicles,
    including motorcycles and high-bed vehicles.
  • Frequency Meter: Following power-up or reset, the
    DEFLECTOMETER® will indicate a 2 or 3 digit number (quickly flashes) that
    indicates the loop frequency of the loop & loop network. Keeping your loops
    separated by at least 5 KHz avoids crosstalk problems and future service calls.
  • Ten (10) Levels of Sensitivity: 10 levels of sensitivity (0
    to 9) can be easily set using the UP or DOWN push buttons.
  • One Model Covers ALL Low Voltages: LMA-1800 operates on
    12VDC, 24VDC, and 24VAC
  • Advanced Loop Diagnostics: The Loop Fault Monitor
    continually checks the integrity of the loops and will report and store 3 types
    of loop faults; Open Loops, Shorted Loops, and 25% sudden changes in
    inductance.
  • Loop Fault Memory: The Loop Fault Memory uses internal
    Non-Volatile memory to store and display the current and previous loop faults
    utilizing the front panel “Loop Fault” LED and DEFLECTOMETER®. A power loss or
    reset will not delete this memory. A MUST FOR TROUBLESHOOTING!
  • Call Output Memory: The detector will not drop a Call state
    if power is lost for a minimum of 4 seconds or less.
  • Two Second Delayed Detection: A 2-second CALL delay time can
    be provided via the program DIP switch.
  • Automatic Tuning
  • Lightning & Surge Protection
  • Four (4) Frequency Levels
  • Compatible with ALL radio controls & remote openers
  • Sensitivity Boost
  • Fail Safe and Fail Secure Configurations
  • Separate Color-Coded LED indicators
  • Wide Loop Inductance Range: 20 to 2500 micro Henries

Plug Compatible with the following Operators:

  • All Linear Operators with APeX controller
  • Advanced Access Automation/FAAC CSL2000, CSW2000, RSW1000
  • All-O-Matic SL100-DC
  • Chamberlain/Elite SL3000, CSW200
  • Intelligate Systems IQ500, IQ5000
  • SECOM Late model operators with 10-pin Molex connectors
  • Rotary Gate Systems SL1000R, SL1000C, SL1000I
  • TyMetal TYM 1000 , TYM 2000
  • Viking Access Models L-3, F-1, T-21, H-10, B-12, Q-4

* All Linear Operators with APeX controller



* Advanced Access Automation/FAAC CSL2000, CSW2000, RSW1000



* All-O-Matic SL100-DC



* Chamberlain/Elite SL3000, CSW200



* Intelligate Systems IQ500, IQ5000



* SECOM Late model operators with 10-pin Molex connectors



* Rotary Gate Systems SL1000R, SL1000C, SL1000I



* TyMetal TYM 1000 , TYM 2000



* Viking Access Models L-3, F-1, T-21, H-10, B-12

All in stock orders typically ship the same business days or within 1-2 business days.  Cut off for same day shipping is 2:30PM Central Time.

LEADTIME

Items with lead times typically ship in 4-7 business days.

FREE SHIPPING POLICY

Orders with free shipping may have longer lead times due to those items being shipped the most economical way.  Free shipping on most orders over $195.00 does not include gate operators, loop sealant, and any extreme length or weight items

Our return policy lasts for only 30 days. If 30 days have gone by since your purchase, unfortunately we can’t offer you a refund. Some items such as Gate Operators or custom parts may not be returnable or carry a restocking fee if returned.

Read return policies

Protec Controls accepts purchase orders please contact us.

NET 30

We also support Net 30 terms on our website for easy ordering. Please fill out the form to the right with your company information and we will get your account setup to place Net 30 orders.

GOVERNMENT & GSA

Protec Controls accepts GSA SmartPay cards along with all major credit cards. For government quotes and purchase orders please email govsales@proteccontrols.com

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Reviews