The EMX ULT-MVP is a single-loop, multi-voltage vehicle loop detector from the ULTRALOOP series. It accepts 12 to 60 VDC or 12 to 240 VAC (48 to 62 Hz), so it does not need to be matched to the operator supply. It plugs into an 11-pin socket or harness (JEDEC B11-88).
It has two SPDT (form C) relays rated 2 A at 30 VDC and 0.5 A at 125 VAC. The second relay can be set for loop fault, pulse on entry or exit, or Detect-On-Stop (output only after the vehicle stops on the loop). The ULTRAMETER display shows the sensitivity setting needed to detect a vehicle on the loop and shows crosstalk. Sensitivity has 10 settings and there are 4 loop frequencies. Other functions: automatic sensitivity boost, delay, fail-safe or fail-secure, and normal (5 minute) or infinite presence. Current draw is 20 mA standby and 50 mA in detect. Loop inductance range is 20 to 2000 µH. Size is 2.9 in x 1.2 in x 3.1 in, weight 0.25 lb, operating temperature -40°F to 180°F. EMX warranty is 2 years. CE compliant.
Before You Order
- Needs an LD-11 DIN rail socket or HAR-11 harness. Neither is included.
- This listing is the US wiring version (ULT-MVP-U).
- A loop is required, such as an EMX PR Lite preformed loop or saw-cut loop wire.
- For two loops on one detector, see the ULT-MVP-2.
- Single channel unit, US wiring (ULT-MVP-U)
- ULTRAMETER™ displays optimum sensitivity setting/crosstalk interference
- 10 sensitivity settings
- 4 operating frequencies
- Automatic sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite or normal (5 min.) presence
- Small size: 73 x 38 x 78mm
- Socket mount -11 pin (JEDEC B11-88)
- CE compliant
- DETECT-ON-STOP allows detection only when a vehicle has come to a complete stop on the loop
- Part Numbers: EMX-2650-1 (ULT-MVP-U, US wiring); EMX-2640-1 (ULT-MVP-E, EU wiring)
- Power: 12-60 VDC or 12-240 VAC (48-62 Hz)
- Operating Current (Standby/Detect): 20 mA / 50 mA
- Loop Frequency: 4 settings (low, med-low, med-hi, high)
- Loop Inductance: 20-2000 µH (Q factor > 5)
- Surge Protection: Loop circuitry protected by surge suppressors
- Presence Relay: SPDT relay contacts (form C)
- Output B Relay: SPDT relay contacts (form C)
- Contact Rating (Resistive Load): 2 A @ 30 VDC, 0.5 A @ 125 VAC
- Operating Temperature: -40 to 180°F (-40 to 82°C), 0 to 95% relative humidity
- Environmental Rating: IP30
- Connector: 11 pin male (JEDEC B11-88), fits DIN rail mount socket or wire harness
- Dimensions (L x W x H): 2.9 x 1.2 x 3.1 in (73 x 38 x 78 mm)
- Sensitivity: 10 levels, 0-9
- ULTRAMETER™ Display: Indicates optimum sensitivity level, 0-9 diagnostic aid
- Loop Frequency: 4 settings (low, med-low, med-hi, high)
- Loop Inductance: 20-2000 µH (Q factor > 5)
- Grounded Loop: Isolation transformer allows operation with poor quality loops
- Automatic Tuning: Detector tunes to loop on power-up and following frequency count function
- Environmental Tracking: Automatic compensation
- Surge Protection: Loop circuitry protected by surge suppressors
- Presence Relay: SPDT relay contacts (form C)
- Output B Relay: SPDT relay contacts (form C)
- Contact Rating (Resistive Load): 2 A @ 30 VDC, 0.5 A @ 125 VAC
- Power / Loop Fault Indicator: Green LED
- Detect / Frequency Count Indicator: Red LED
- Detect-On-Stop™: Requires vehicle to stop for a minimum of 1 second (1-2 s typical)
- ASB (Automatic Sensitivity Boost): Increases sensitivity after initial detection to prevent dropout due to high-bed vehicles
- Power: 12-60 VDC (max. 0.8 VA), 12-240 VAC 48-62 Hz (max. 1.4 VA)
- Operating Current: 20 mA standby / 50 mA detect
- Operating Temperature: -40 to 180°F (-40 to 82°C), 0 to 95% relative humidity
- Dimensions (L x W x H): 2.9 x 1.2 x 3.1 in (73 x 38 x 78 mm)
- Weight: 0.25 lb (113 g)
- Housing: ABS plastic, IP30
- Connections: Socket mount, 11 pin male (JEDEC B11-88)
Ordering Information
- ULT-MVP-U: Ultra MVP multi-voltage vehicle loop detector, dual output, AC or DC power, US wiring
- ULT-MVP-E: Ultra MVP multi-voltage vehicle loop detector, dual output, AC or DC power, EU wiring
- HAR-11: 3 ft 11 pin harness
- LD-11: 11 pin socket base, DIN rail mount
- PR-XX: EMX Lite preformed loop with lightning protection (XX = size)
Manuals & Support: installation manuals, wiring diagrams and troubleshooting
Used with an inductive loop to detect vehicles at gates, doors, barrier arms and drive-thru lanes.
- Vehicle gate operators
- Garage and overhead door operators
- Parking barrier arms
- Free exit, reverse and center loops
- Drive-thru lanes
- Operator supplies from 12 VDC to 240 VAC
All in stock orders typically ship the same business days or within 1-2 business days. Cut off for same day shipping is 2:30PM Central Time.
LEADTIME
Items with lead times typically ship in 4-7 business days.
FREE SHIPPING POLICY
Orders with free shipping may have longer lead times due to those items being shipped the most economical way. Free shipping on most orders over $195.00 does not include gate operators, loop sealant, and any extreme length or weight items
Our return policy lasts for only 30 days. If 30 days have gone by since your purchase, unfortunately we can’t offer you a refund. Some items such as Gate Operators or custom parts may not be returnable or carry a restocking fee if returned.
Protec Controls accepts purchase orders please contact us.
NET 30
We also support Net 30 terms on our website for easy ordering. Please fill out the form to the right with your company information and we will get your account setup to place Net 30 orders.
GOVERNMENT & GSA
Protec Controls accepts GSA SmartPay cards along with all major credit cards. For government quotes and purchase orders please email govsales@proteccontrols.com